Grade X6CrNiMoNb17-12-2
1.4580
Corresponding Standard NF EN 10028-7-2008
Flat products made of steels for pressure purposes - Part 7 : stainless steels
Classification Austenitic Stainless Steel
X6CrNiMoNb17-12-2 Chemical Element Composition Content (%)
Component C Si Mn P S Cr Ni Mo More
Minimum Value - - - - - 16.5 10.5 2 Nb:10×C~1
Maximum Value 0.08 1 2 0.045 0.015 18.5 13.5 2.5
◎ Elements not quoted in this table shall not be intentionally added to the steel without the agreement of the purchaser except for finishing the cast. All precautions are to be taken to avoid the addition of such elements from scrap and other materials used in production which would impair mechanical properties and the suitability of the steel.
X6CrNiMoNb17-12-2 Mechanical Properties
condition Heat Treatment or Condition
Tensile Strength
σb
Mpa
Yield Point
σs
Mpa
Elongation or Extension Rate
δ
%
Impact Energy Absorption
KV2
J
P:T ≤ 75 +AT 520~720 Rp0.2:≥220
Rp1.0:≥260
①②
T < 3mm: ≥40
T ≥ 3mm: ≥ 40
②③
20℃:
(l: ≥100;t: ≥60)
◎ C-Cold rolled strip;H-Hot rolled strip;P-Hot rolled plate;T-Thickness;t-transverse;l-Longitudinal
◎ +A=annealed;+AT=solution annealed;+QT = quenched and tempered;+RA=recrystallizing annealed condition
◎ Austenitic steels always have adequate toughness and do not need to be impact tested. In contrast, austenitic-ferritic steels need to be tested to the impact energy requirements ensure that toughness is adequate.
* Resistance to intergranular corrosion when tested according to EN ISO 3651-2. In the delivery condition: yes;In the sensitized condition: yes.
① For continuously hot-rolled products, 20N/mm² higher minimum values of Rp0,2 and 10N/mm² higher minimum values of Rp1,0 may be agreed at the time of enquiry and order.
② If, in the case of strip in rolling widths < 300 mm, longitudinal test pieces are taken, the minimum values are reduced as download:proof strength: minus 15 N/mm²,elongation for constant gauge length: minus 5 %,elongation for proportional gauge length: minus 2 %
③ T<3mm:This value applies to specimens with a gauge length of 80 mm and a width of 20 mm. Specimens with a gauge length of 50 mm and a width of 12.5 mm may also be used. T ≥3mm:This value applies to specimens with a gauge length of 5.65√S

Note: The data is for reference only! If you have any questions, please fill out "I want to correct it"!